Bộ cách ly tín hiệu MCR-SL-UI-2I-NC
Thông số kỹ thuật Phonix MCR-SL-UI-2I-NC
| Ambient temperature (operation) | -20 °C … 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C … 85 °C |
| Permissible humidity (operation) | 10 % … 95 % (non-condensing) |
| Degree of protection | IP20 |
| Noise immunity | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
| Number of inputs | 1 |
|---|---|
| Configurable/programmable | Yes, unconfigured |
| Voltage input signal | 0 V … 10 V (please indicate if different setting when ordering) |
| 1 V … 5 V | |
| Current input signal | 0 mA … 20 mA |
| 4 mA … 20 mA | |
| max. input voltage | 30 V |
| Max. input current | 50 mA |
| Input resistance of voltage input | approx. 100 kΩ |
| Input resistance current input | approx. 50 Ω |
| Number of outputs | 2 |
|---|---|
| Configurable/programmable | Yes, unconfigured |
| Current output signal | 2x 0 mA … 20 mA |
| 2x 4 mA … 20 mA | |
| Max. output current | approx. 22 mA |
| Load/output load current output | ≤ 250 Ω (at 20 mA) |
| Ripple | < 20 mVPP (at 250 Ω) |
| Nominal supply voltage | 24 V DC |
|---|---|
| Supply voltage range | 19.2 V DC … 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715)) |
| Max. current consumption | < 30 mA (at 24 V DC incl. load) |
| Power consumption | < 600 mW |
| Connection method | Screw connection |
|---|---|
| Stripping length | 12 mm |
| Screw thread | M3 |
| Conductor cross section solid | 0.2 mm² … 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² … 2.5 mm² |
| Conductor cross section AWG | 26 … 12 |
đại lý phoenix contact | nhà phân phối phoenix contact
| No. of channels | 2 |
|---|---|
| Maximum transmission error | ≤ 0.2 % (of final value) |
| Transmission error, typical | < 0.1 % |
| Maximum temperature coefficient | < 0.01 %/K |
| Temperature coefficient, typical | < 0.004 %/K |
| Limit frequency (3 dB) | approx. 35 Hz |
| Protective circuit | Transient protection |
| Electrical isolation | Basic insulation according to EN 61010 |
| Overvoltage category | II |
| Degree of pollution | 2 |
| Rated insulation voltage | 50 V AC/DC |
| Test voltage, input/output/supply | 1.5 kV (50 Hz, 1 min.) |
| Electromagnetic compatibility | Conformance with EMC directive |
| Noise emission | EN 61000-6-4 |
| Noise immunity | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
| Color | green |
| Housing material | PBT |
| Mounting position | any |
| Assembly instructions | The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715. |
| Conformance | CE-compliant |
| ATEX | II 3 G Ex nA IIC T4 Gc X |
| UL, USA/Canada | UL 508 Recognized |
| Class I, Div. 2, Groups A, B, C, D T5 | |
| GL | GL EMC 2 D |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 – HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 – HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 – HL 2 |
| Designation | Electromagnetic RF field |
|---|---|
| Standards/regulations | EN 61000-4-3 |
| Typical deviation from the measuring range final value | 5 % |
| Designation | Fast transients (burst) |
| Standards/regulations | EN 61000-4-4 |
| Typical deviation from the measuring range final value | 5 % |
| Designation | Conducted interferences |
| Standards/regulations | EN 61000-4-6 |
| Typical deviation from the measuring range final value | 5 % |




Đánh giá
Chưa có đánh giá nào.