STT Relay Type Thông số kỹ thuật
1 Rơ le CAEM21 2NO SR Battery E/F relay Self Powered Battery voltage 24, 48, 110, 220V DC Setting 1 to 7mA, Aux Contacts 2NO SR & 3NC+1NO SR Flag
2 Rơ le CAEM33 Second Rotar E/F relay
3 Rơ le CAG11 AC Instantaneous O/C Relay
4 Rơ le CAG12 AC Instantaneous O/C or E/F relay 2 N/O S/R
5 Rơ le CAG12C AC Instantaneous O/C or E/F relay 1NO+1NC S/R contacts O/C 50- 200% & E/F 20-80% or 10-40% of 5A or 1A
6 Rơ le CAG14 1ph AC Instantaneous circulating current relay with tuned circuits & adjustable setting 10-40% or 20- 80% of 5A or 1A with external Stabilizing resistor & 2NO SR contacts.
7 Rơ le CAG14 1 Pole AC Instantaneous O/C relay 5A or 1A; 250-2000% or 200-800% 2 NO S/R.
8 Rơ le CAG34 3ph AC Instantaneous circulating current relay with tuned circuits & adjustable setting 10-40% or 20- 80% of 5A or 1A with external Stabilizing resistor & 2NO SR contacts.
9 Rơ le CAG34 3 Pole AC Instantaneous O/C relay 5A or 1A; 250-2000% or 200-800% 2 NO S/R.
10 Rơ le CCUM21 Sensitive instantaneous voltage polarised directional relay with integral timer relay (reverse power aux) 2NO SR Contacts & aux. supply 30/110/220V DC CTR 5A or 1A PT volts 110V AC MTA 30 & timing .5-5 or 1-10, 2.5-25 sec
11 Rơ le CDAG31 IDMT relay with 2 O/C CDG11 & 1 E/F CAG14 2NO SR self powered
12 Rơ le CDAG51 Non-directional IDMT relay 2 O/C 50-200% with highset setting 250 – 2000% type CAG17 & E/F relay setting 10-40% or 20-80% type CAG14 CTR 5A or 1A self powered 2NO S/R contacts
13 Rơ le CDD21 Directional IDMT voltage current polarized O/C or E/F relay 2NO SR / 2NO HR setting O/C 50-200% or 10-40% of 5 or 1A CTR. Single Pole
14 Rơ le CDG11 1 Pole Non-Directional 3VA IDMT O/C or E/F or O/C & E/F relay 2NO S/R / 2NO+2NC HR contact setting O/C 50-200% & E/F 20-80% or 10-40% of 5A or 1A Self powered. DMT 3 / 1.3 Sec
15 Rơ le CDG12 1 Pole Inverse time (long time delay) stand by earth fault relay 15-20% 5A or 1A 2NO S/R / H/R Aux. DC.
16 Rơ le CDG13 1 Pole IDMT relay O/C or E/F 5A or 1A 1.5 Sec. 2 NO S/R / H/R & DC aux
17 Rơ le CDG14 1 Pole IDMT extremely inverse time O/C or E/F 5A or 1A
18 Rơ le CDG21 Non-directional IDMT O/C or E/F relay O/C 50-200%, E/F 20-80% or 10-40% fitted with highest relay type CAG17 O/C 200-2000% E/F 100-800% CTR 5A or 1A 2NO S/R or 2NO + 2NC HR self powered.
19 Rơ le CDG24 IDMT extremely inverse time O/C or E/F 5A or 1A
20 Rơ le CDG31 3 Pole Non-Directional 3VA IDMT O/C or E/F or O/C & E/F relay 2NO S/R / 2NO+2NC HR contact setting O/C 50-200% & E/F 20-80% or 10-40% of 5A or 1A Self powered. DMT 3 / 1.3 Sec
21 Rơ le CDG33 3 Pole IDMT relay O/C or E/F 5A or 1A 1.5 Sec. 2 NO S/R / H/R & DC aux
22 Rơ le CDG34 3 Pole IDMT extremely inverse time O/C or E/F 5A or 1A
23 Rơ le CDGM12 3 Pole IDMT extremely inverse time O/C or E/F 5A or 1A
24 Rơ le CDV62 Non-directional IDMT 3 O/C relay with U/V control 2NO S/R contact adjustable setting 50-200% of 5A or 1A 2NO S/R. –do– 2NO H/R
25 Rơ le CTIGM15 Static single pole instaneneous sensitive E/F relay.
26 Rơ le CTMFM401-410 Static Motor Protection relays for Motors controlled by Circuit Brks. -do- but controlled by Contactors
27 Rơ le CTMM501-510 Static Motor Protection relays for Motors controlled by Circuit Brks. -do- but controlled by Contactors
28 Rơ le CTNM12 Definite time negative phase seq. current relay for single phasing & unbalance detection. CTR 5A or 1A volt 110/250V AC/DC setting 10% or 20% time 3/6/9 sec.
29 Rơ le CTNM31 Static Negative phase seq. Relay Extra for one heavy current test plug and extention cord for above
30 Rơ le CTU12 1 Pole Static definite time O/C or E/F relay
31 Rơ le CTU15 1 Pole Sensitive definite time Static E/F relay
32 Rơ le CTU32 3 Pole Static definite time O/C or E/F relay
33 Rơ le CTUM15 1 Pole Sensitive definite time Static E/F relay
34 Rơ le DTH31 High speed differential relay for two winding transformer CTR 5A or 1A diff. setting 15% Bias setting 15-30-45% Aux voltage 24/30/110 /220V DC 2NO S/R.
35 Rơ le DTH32 High speed differential relay for two winding transformer CTR 5A or 1A diff. setting 15% Bias setting 15-30-45% Aux voltage 24/30/110 /220V DC 2NO S/R.
36 Rơ le VAA11YF0752BA
Sensitive Earth Leakage relay to be used with CBCT (extra cost)
37 Rơ le FAC14 1 Pole High Impedance Differential relay
38 Rơ le FAC34 3 Pole High Impedance Differential relay
39 Rơ le GTT21 Definite Time Over Fluxing relay
40 Rơ le GTTM22 Definite Time Over Fluxing relay
41 Rơ le HORM4 Feeder Protection Relay Set Using Pvt. Pilots with facility to supervise the healthness of pilots comprising of Relays for (a) Sending End (b) Receiving End (c) Injection Unit (d) Measuring & Pilot supervision unit
42 Rơ le MBCH12 1-Phase Transformer diff. Relay. 2 winding Transformer
43 Rơ le MBCH13 1-Phase Transformer diff. Relay. 3 winding Transformer
44 Rơ le MCAG14 Single pole high stability circulatng current relay
45 Rơ le MCAG34 3 pole high stability circulatng current relay
46 Rơ le MCTGM11 Static Inv. time 1-Ph O/C or E/F relay with std. Inv. Time charc
47 Rơ le MCTGM21 Static Inv. time 1-Ph O/C or E/F relay with inst. Highset unit
48 Rơ le MCTIG40-L Breaker Backup relay 3-Pole
49 Rơ le MFVUM12 Digital Over/Under frequency protective relay. Single Stage
50 Rơ le MFVUM22 Digital Over/Under frequency protective relay. Two Stage
51 Rơ le MPB Test Plug Universal Test Block
52 Rơ le MVAJM11
Test Plug Universal Test Block
53 Rơ le MVAAM11 Aux relay 2M & 2C/O S/R contact
54 Rơ le MVAAM13 Aux relay 2M & 2C HR Contacts
55 Rơ le MVAAM21 Aux relay 2M & 2C/O S/R contact with 2 elements & 4 C/O
56 Rơ le MVAAM23 Aux relay 4M & 4C HR Contacts
57 Rơ le MVAAM31 Aux relay 2M & 2C/O S/R contact with 3 elements & 4 C/O
58 Rơ le MVAAM41 Aux relay 2M & 2C/O S/R contact with 4 elements & 8 C/O
59 Rơ le MVAAM51 Aux relay 2M & 2C/O S/R contact with 5 elements & 8 C/O
60 Rơ le MVAAM61 Aux relay 2M & 2C/O S/R contact with 6 elements & 8 C/O

 